26 l_lcb_acctounit - acceleration value conversion, The l_lcb_logiccontrolbasic library – Lenze PLC Designer R3-x User Manual

Page 144

Advertising
background image

The L_LCB_LogicControlBasic library

L_LCB_AccToUnit - acceleration value conversion

144

Lenze · Commissioning of Lenze drives · 1.3 EN - 06/2014

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

13.26

L_LCB_AccToUnit - acceleration value conversion

This FB converts an acceleration value specified in the internal unit [rpm/s] to an acceleration value

in the real unit of the machine on the basis of the machine parameters transmitted.

Inputs

Outputs

Function library:

L_LCB_LogicControlBasic

Runtime software licence:

LPC 1x00

MPC 1x00

MPC 2xx0

MPC 3x00

L_LCB_AccToUnit

DINT ⎯ diAccIn_x

diAccOut_e4 ⎯ DINT

L_LCB_SetAxisData -

machine parameters

⎯ scAxisData

xLimit ⎯ BOOL

xError ⎯ BOOL
eError ⎯

L_LCB_Error

Identifier/data type

Information/possible settings

diAccIn_x

DINT

Acceleration as speed variation/time

in [rpm/s] 15000 rpm/s ≡ 2

22

= 4194304

scAxisData

L_LCB_SetAxisData -

machine parameters

Machine parameters

Identifier/data type

Information/possible settings

diAccOut_e4

DINT

Acceleration in unit/s

2

]

• Display in "e4" view (fixed point with four decimal positions)

xLimit

BOOL

"Output signal is limited" status

• TRUE: The output signal is limited to the representable value range

±214748.3647

xError

BOOL

"Error" status signal

FALSE Conversion carried out without errors

TRUE Error during the conversion

eError

L_LCB_Error

Error number, error code

Advertising