Extending sample projects - adding devices

Creating a control configuration - EtherCAT bus system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8

Extending sample projects - adding devices

This chapter informs you on how to extend the control configuration manually.

• Lenze provide ready-made sample projects in which the control configuration has already been

created. More information can be found in the following section:

Working with the sample

projects

( 23)

• Proceed as described below to extend an existing sample project individually. Please note that

the communication settings have to be adapted for each individual node.

8.1

Creating a control configuration - EtherCAT bus system

How to create the control configuration in the »PLC Designer«:

1. Open the context menu of the target system and execute the command

Append device

in order to extend the control configuration with

"EtherCAT Master".

Note!

Before creating an EtherCAT configuration in »PLC Designer«, ensure that the following

conditions have been met:

• The sequence of EtherCAT slaves in the device tree must correspond to the physical

arrangement of the EtherCAT topology.

• In order that the system works properly, end terminals must not be used when setting

up the system configuration in the device tree.

• Select the cycle times according to the technical data, from 1 ... 10 ms.