Appendix B –

Serial Communications

B-3

Table B.2 Logic Control Data

This information will be displayed in the controller’s output image table and will be sent to
the drive when the appropriate dip switch setting on the Communication Module is enabled.

Logic Bits

Status

Text

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

S a

Tex

X

Stop

1

=

Stop, 0

=

Not Stop

X

Start

1

=

Start, 0

=

Not Start

X

Jog

1

=

Jog, 0

=

Not Jog

X

Clear Faults

1

=

Clear Faults 0

=

Not Clear Faults

X

X

Direction

00

=

No Command

01

=

Forward Command

10

=

Reverse Command

11

=

Hold Direction Control

X

Local

1

=

Local Lockout, 0

=

Not Local

X

MOP Increment

1

=

Increment, 0

=

Not

X

X

Accel Time

00

=

No Commd

01

=

Accel Time 1 Commd

10

=

Accel Time 2 Commd

11

=

Hold Accel Time Ctrl

X

X

Decel Time

00

=

No Commd Time

01

=

Decel Time 1 Commd

10

=

Decel Time 2 Commd

11

=

Hold Time Ctrl

X

X

X

Reference
Select

000

=

No Command Select

001

=

[Freq Select 1] (Selectable)

010

=

[Freq Select 2] (Selectable)

011

=

[Preset Freq 3]

100

=

[Preset Freq 4]

101

=

[Preset Freq 5]

110

=

[Preset Freq 6]

111

=

[Preset Freq 7]

X

MOP Dec

1

=

Decrement, 0

=

Not