Rockwell Automation 1305 AC Drive, Series A and B, Firmware 4.xx-5.xx User Manual

Page 42

Advertising
background image

ESC

SEL

JOG

Chapter 3 – Human Interface Module

3-2

Display Panel Descriptions

Escape
When pressed, the ESC key will cause the
programming system to go back one level in the
menu structure.

Select
Pressing the SEL key alternately moves the cursor to
the next active area. A flashing first character
indicates which line is active.

Increment/Decrement
These keys are used to increment and
decrement a value or scroll through different
groups or parameters.

Enter
When pressed, a group or parameter will be selected
or a parameter value will be entered into memory.
After a parameter has been entered into memory, the
top line of the display will automatically become
active, allowing another parameter (or group) to be
chosen.

Control Panel Descriptions

IMPORTANT:The following information is correct as shipped
from the factory. Reprogramming of mask parameters can mask
out control of some of these functions.

Start
The Start key will initiate drive operation if no other
control devices are sending a Stop command. This
key can be disabled by the [Logic Mask] or [Start
Mask]
.

Stop
If the drive is running, pressing the Stop key will
cause the drive to stop, using the selected stop mode.
Refer to the [Stop Select] in Chapter 5.

If the drive has stopped due to a fault, pressing this
key will clear the fault and reset the drive. Refer to
the [Flt Clear Mode], [Logic Mask] and [Fault
Mask]
parameters.

Jog
When pressed, jog will be initiated at the frequency
set by the [Jog Frequency] parameter, if no other
control devices are sending a Stop command.
Releasing the key will cause the drive to stop, using
the selected stop mode. Refer to [Stop Select], [Logic
Mask]
and [Jog Mask].

IMPORTANT:If the drive is running prior to issuing
a jog command, the jog command will be ignored.

IMPORTANT:A start command from another source
will override the jog command.