Command Reference Manual

100722A

Conexant

4-1

4.

FAX CLASS 1 AND FAX CLASS 1.0 COMMANDS

4.1

FAX I/O PROCESSING

The fax I/O interface supports asynchronous serial and parallel interfaces. The character format is 8 bits data, no parity, and 1
stop bit. Start and stop elements are removed from the transmit data and added to the receive data. Both transmit and
receive data are buffered. Flow control using XON/XOFF or RTS/CTS is provided.

Unique control character strings are identified, filtered, or reinserted into the I/O data stream. These control characters and
their resultant action are described below.

4.1.1

DTE-to-Modem Transmit Data Stream

Characters Detected

Action Taken

<DLE><data>

Delete <DLE><data> characters.

<DLE><ETX>

Recognize as a string terminator and take appropriate action.

<DLE><DLE>

Replace with single <DLE> character.

4.1.2

Modem-to-DTE Receive Data Stream

Characters Detected

Action Taken

<DLE>

Insert extra <DLE> ahead of <DLE>.

The modem also identifies the end of a frame by inserting <DLE><ETX> into the data stream after the FCS bytes.

4.1.3

Fax Mode Selection

Fax Class 1 and Fax Class 1.0 commands are identified in Table 4-1. Fax Class 1.0 includes all Fax Class 1 commands.

Table 4-1. Fax Class 1 and Fax Class 1.0 Commands

Command/Parameter

Function

Applicable in

Fax Class 1

Applicable in

Fax Class 1.0

+FCLASS=<class>

Select, read or test service class

X

X

+FAA=<value>

Auto answer enable

-

X

+FAE=<value>

Auto answer enable

X

X

+FTS=<time>

Stop transmission and pause

X

X

+FRS=<time>

Wait for silence

X

X

+FTM=<mod>

Transmit data with <mod> carrier

X

X

+FRM=<mod>

Receive data with <mod> carrier

X

X

+FTH=<mod>

Transmit HDLC data with <mod> carrier

X

X

+FRH=<mod>

Receive HDLC data with <mod> carrier

X

X

+FAR=<off/on>

Adaptive reception control

-

X

+FCL=<time>

Carrier loss timeout

-

X

+FDD=<value>

Double escape character replacement control

-

X

+FIT=<time>, <action>

DTE inactivity timeout

-

X

+FPR=<rate>

Fixed DTE Rate

-

X

+FMI?

Report manufacturer ID

-

X

+FMM?

Report model ID

-

X

+FMR?

Report revision ID

-

X

+FLO

Flow Control

-

X

&K

Local DTE-modem flow control (see Section 3.2.2.8)

X

X

A

Answer (see Section 3.2.3.4)

X

X

D

<string>

Dial (see Section 3.2.3.1)

X

X

H

Hangup (see Section 3.2.3.5)

X

X

X = Applicable; - = Not applicable.