3.3.3.12 S11 - DTMF Tone Duration
S11 operation is country dependent.

1.

For US models, S11 sets the duration of tones in DTMF dialing (has no effect on pulse dialing).

2.

For W-class models, S11 is a country parameter loaded by ConfigurACE.

Range:

50-255 milliseconds

Default: 95 (95 milliseconds)

3.3.3.13 S12 - Escape Prompt Delay (EPD)
S12 defines the maximum period, in fiftieths of a second, allowed between receipt of the last character of the three escape
character sequence from the DTE and sending of the OK result code to the DTE. If any characters are detected during this
time, the OK will not be sent. Sending of the OK result code does not affect entry into command mode. (See 3.1.3.)

Range:

0-255 1/50 of a second

Default: 50 (1 second)

3.3.3.14 S14 - General Bit Mapped Options Status
S14 indicates the status of command options.

Default: 138 (8Ah) (10001010b)

Bit 0

This bit is ignored.

Bit 1

Command echo (En)

0 =

Disabled (E0)

1 =

Enabled (E1) (Default.)

Bit 2

Quiet mode (Qn)

0 =

Send result codes (Q0) (Default.)

1 =

Do not send result codes (Q1)

Bit 3

Result codes (Vn)

0 =

Numeric (V0)

1 =

Verbose (V1) (Default.)

Bit 4

Reserved

Bit 5

Tone (T)/Pulse (P)

0 =

Tone (T) (Default.)

1 =

Pulse (P)

Bit 6

Reserved

Bit 7

Originate/Answer

0 =

Answer

1 =

Originate (Default.)