Conexant – Comtrol AT Commands for SmartACFL User Manual

Page 77

Advertising
background image

Command Reference Manual

100722A

Conexant

3-57

Table 3-3. AT#UD Last Call Status Report Format

Key

Value(s)

Definition

0

2 digits

Diagnostic Command Specification revision number, digit.digit

1

Table 3-4

Call Setup Result code

2

Table 3-5

Multi-media mode

3

Table 3-6

DTE-DCE interface mode

4

String

V.8 CM octet string, same format as V.250, in quotes

5

String

V.8 JM octet string, same format as V.250, in quotes

10

0-2F

Received signal power level, in –dBm (0-43)

11

0-1F

Transmit signal power level, in –dBm (e.g., 0-17)

12

0-64

Estimated noise level, in –dBm (e.g., 10-90)

17

0-FFF

Round Trip delay, in units of ms

18

Table 3-7

V.34 INFO bit map

20

Table 3-8

Transmit Carrier Negotiation Result

21

Table 3-8

Receive Carrier Negotiation Result

22

0-1F40

Transmit Carrier symbol rate (0-8000) in symbol/s

23

0-1F40

Receive Carrier symbol rate (0-8000) in symbol/s

24

0-FA0

Transmit Carrier frequency (0-4000) in Hz

25

0-FA0

Receive Carrier frequency (0-4000) in Hz

26

0-FA00

Initial transmit carrier data rate (0-64000) in bit/s

27

0-FA00

Initial receive carrier data rate (0-64000) in bit/s

30

0-FF

Temporary carrier loss event count

31

0-FF

Carrier Rate re-negotiation event count

32

0-FF

Carrier Retrains requested

33

0-FF

Carrier Retrain requests granted

34

0-FA00

Final transmit carrier data rate in bit/s

35

0-FA00

Final receive carrier data rate in bit/s

40

Table 3-9

Protocol Negotiation Result

41

0-400

Error Control frame size in bytes

42

0-FF

Error control link timeouts in transmission

43

0-FF

Error control link NAKs received

44

Table 3-10

Compression Negotiation Result

50

0-2

Transmit flow control: 0 = off; 1 = DC1/DC3; 2 = V.24 circuit 106/133

51

0-2

Receive flow control: 0 = off; 1 = DC1/DC3; 2 = V.24 circuit 106/133

52

0-FFFFFFFF

Transmit characters sent from DTE

53

0-FFFFFFFF

Received characters sent to DTE

54

0-FFFF

Transmit characters lost (data overrun errors from DTE)

55

0-FFFF

Received characters lost (data overrun errors to DTE)

56

0-FFFFFFFF

Transmit I- Frame count, if error control protocol running

57

0-FFFFFFFF

Received I-Frame count, if error control protocol running

58

0-FFFF

Transmit I-Frame error count, if error control protocol running

59

0-FFFF

Received I- Frame error count, if error control protocol running

60

Table 3-11

Termination Cause

61

0-FF

Call Waiting event count

Advertising