Comtrol AT Commands for SmartACFL User Manual

Page 59

Advertising
background image

Command Reference Manual

100722A

Conexant

3-39

+MCR: Report Syntax
Response:

+MCR: <carrier>

<carrier>

Alphanumeric code corresponding to the reported carrier. Defined values are:

B103

For Bell 103

B212

For Bell 212

V21

For V.21

V22

For V.22

V22B

For V.22bis

V23C

For V.23

V32

For V.32

V32B

For V.32bis

V34

For V.34

V90

For V.90

K56

For K56flex

+MRR: Report Syntax
Response:

+MRR: <tx_rate>,<rx_rate>

<tx_rate>

Decimal transmit rate in bits/s.

<rx_rate>

Decimal receive rate in bits/s.

Example:

+MRR: 28800, 48000

3.2.4.3 %E - Enable/Disable Line Quality Monitor and Auto-Retrain or Fallback/Fall Forward
Controls whether or not the modem will automatically monitor the line quality and request a retrain (%E1) or fall back when
line quality is insufficient or fall forward when line quality is sufficient (%E2). The parameter value, if valid, is written to S41
bits 2 and 6.

If enabled, the modem attempts to retrain for a maximum of 30 seconds.

Syntax

%E<value>

Defined Values

<value>

Decimal number corresponding to the selected option.

0

Disable line quality monitor and auto-retrain.

1

Enable line quality monitor and auto-retrain.

2

Enable line quality monitor and fallback/fall forward. (Default.)

Result Codes

OK

<value> = 0, 1, or 2.

ERROR

Otherwise.

Fallback/Fall Forward. When %E2 is active, the modem monitors the line quality (EQM). When line quality is insufficient, the
modem will initiate a rate renegotiation to a lower speed within the V.34/V.32 bis/V.32 (RC336) modulation speeds. The
modem will keep falling back within the current modulation if necessary until the speed reaches 2400 bps (V.34) or 4800 bps
(V.32). Below this rate, the modem will only do retrains if EQM thresholds are exceeded. If the EQM is sufficient for at least
one minute, the modem will initiate a rate renegotiation to a higher speed within the current modulation speeds. The rate
renegotiations will be done without a retrain if a V.32 bis connection is established.

Speeds attempted during fallback/fall forward are those shown to be available in the rate sequences exchanged during the
initial connection. Fallback/fall forward is available in error correction and normal modes, but not in direct mode or
synchronous mode with external clocks.

Advertising
This manual is related to the following products: