4.2.2.7 +FTH - Transmit Data with HDLC Framing
This command causes the modem to transmit data using HDLC protocol and the modulation defined below.

Syntax

+FTH=<mod>

Defined Values

<mod>

Decimal number corresponding to the selected modulation mode and data rates shown in Table
4-2.

Result Codes

CONNECT

Reported for either of two conditions:

1. At the beginning of transmission of the training pattern for the selected modulation.
2. If the Final Frame bit is 0.

OK

Reported for either of two conditions:

1. If the Final Frame Bit is 1.
2. if the DTE sends only <DLE><ETX> (a null frame) while transmitting flags.

ERROR

Reported if five seconds elapse from the time when the modem reported the CONNECT result
code without any additional data transmitted from the DTE; the modem then turns off carrier and
returns to the command mode.

Reporting Current or Selected Values
Command: +FTH?
Response:

+FTH: <mod>

Example:

+FTH: 98

For V.17 9600 bps.

Reporting Supported Range of Parameter Values
Command: +FTH?
Response:

+FTH?

Example:

+FTH: 98

For V.17 9600 bps.