3.2.3.13 \V - Single Line Connect Message Enable
This command enables or disables the single line connect message format as follows:

Syntax

\V<value>

Defined Values

<value>

Decimal number corresponding to the selected option.

0

Connect messages are controlled by the command settings X, W, and S95.

1

Connect messages are displayed in the single line format described below subject
to the command settings V (Verbose) and Q (Quiet). In Non-Verbose mode (V0),
single line connect messages are disabled and a single numeric result code is
generated for CONNECT DTE.

When single line connect messages are enabled, there are no CARRIER, PROTOCOL (+ER:), or COMPRESSION (+DR:)
messages apart from the fields described below.

The single line connect message format is:

CONNECT <DTE Speed>/<Modulation>/<Protocol>/<Compression>/<Line Speed>/<Voice and Data>

Where:

DTE Speed =

DTE speed, e.g., 57600.

Modulation =

“V90” for V.90 modulation.
“K56” for K56flex modulation.
“V34” for V.34 modulation.
“V32” for V.32 or V.32bis modulation.
Note: Modulation is omitted for all other modulations.

Protocol =

“NONE” for no protocol.
“ALT” for Microcom Network Protocol.
“LAPM” for LAP-M protocol.

Compression =

“ALT” for Microcom MNP5 compression.
“V42B” for V.42bis compression.
Note: Compression is omitted if protocol is NONE.

Line Speed =

Asymmetric rates are displayed as /rate:TX/rate:RX, e.g., /1200 TX/75 RX.
Symmetric rates are displayed as a single DCE rate, e.g., 14400.

Voice and Data =

Blank for Data mode only.
“SVD” for AudioSpan analog simultaneous audio/voice and data.
“DSVD” for digital simultaneous voice and data.
“V70” for G.729A digital simultaneous voice and data.

3.2.3.14 %L - Report Line Signal Level
Returns a value which indicates the received signal level. The value returned is a direct indication (DAA dependent) of the
receive level at the MDP, not at the telephone line connector. For example, 009 = -9 dBm, 043 = -43 dBm, and so on.

Result Codes