+FDCS - Current Session Results Parameters

Read syntax:

+FDCS?

DCE response:

+FDCS=VR,BR,WD,LN,DF,EC,BF,ST

or

+FDCS=

Valid values:

See Table 5-2.

Default values:

0,0,0,0,0,0,0,0

The +FDCS parameter is loaded with the negotiated T.30 parameters for the current session. A transmitting DCE generates
DCS; a receiving DCE gets DCS from the remote station. The DTE may read this parameter.

The +FDCS parameter is initialized 0,0,0,0,0,0,0,0 upon initialization and at the beginning of a session. If the DTE issues a
+FDCS? command in the initial state, the DCE reports:

<CR><LF>0,0,0,0,0,0,0,0<CR><LF>

The contents of +FDCS are spontaneously reported during execution of +FDR or +FDT commands by the
+FDCS:VR,BR,WD,LN,BF,EC,BF,ST response using the same compound parameter format.

Several commands and responses reference T.30 session negotiated parameters. These are described by a set of common
subparameters. These subparameters are described in Table 5-2 with notes. Optional parameter values are marked with an *.
Unspecified parameter values are reserved for future use.

The +FDCC, +FDIS, and +FDCS compound parameters use these session parameters (On writes, unspecified
subparameters are unchanged.)

The +FDIS:, +FDCS:, and +FDTC: session report responses use these subparameters.

For test response, ranges of values are reported for each subparameter enclosed in parentheses characters. For example, a
DCE response to +FDCC=? could report:

<CRLF> (0,1), (0-5), (0-3), (0-2), (0-2), (0-2), (0), (0-7) <CRLF> (14400 fax models)

Example:

+FDIS=0,5,0,2,0,0,0,1 =

VR = 0

98 dpi vertical resolution,

BR = 5

14400 bit/s

WD = 0

1728 pixels,

LN = 2

unlimited length

DF = 0

1-D modified Huffman coding,

EC = 0

no ECM,

BF = 0

no BFT,

ST = 1

5 ms scan time.