Comtrol AT Commands for SmartACFL User Manual

Page 47

Advertising
background image

Command Reference Manual

100722A

Conexant

3-27

3.2.3.6 O - Return to On-Line Data Mode
This command determines how the modem will enter the on-line data mode. If in the on-line command mode, the modem
enters the on-line data mode with or without a retrain. If in the off-line command mode (no connection), the modem reports
ERROR.

Syntax

O<value>

Defined Values

<value>

Decimal number corresponding to the selected option.

0

Enters on-line data mode without a retrain. Handling is determined by the Call
Establishment task. Generally, if a connection exists, this command connects the
DTE back to the remote modem after an escape (+++).

1

Enters on-line data mode with a retrain before returning to on-line data mode.

2

Fast retrain without speed change (used for diagnostic purpose only).

3

Renegotiate rate without speed change (used for diagnostic purpose only.

4

Renegotiate rate down one speed (used for diagnostic purpose only).

5

Renegotiate rate up one speed (used for diagnostic purpose only).

Result Codes

OK

<value> = 0 to 5 and a connection exists.

ERROR

Otherwise or if not connected.

3.2.3.7 L - Speaker Volume
This command sets the speaker volume control. The parameter value, if valid, is written to S22 bits 0 and 1.

Syntax

L<value>

Defined Values

<value>

Decimal number corresponding to the selected option.

0

Low volume.

1

Low volume. (Default.)

2

Medium volume.

3

High volume.

Result Codes

OK

<value> = 0 to 3.

ERROR

Otherwise.

Advertising