Command Reference Manual

100722A

Conexant

5-11

5.3.7

+FCIG - Set Polling ID

This command allows setting the Local Polling ID string used in a CIG frame. The syntax of this command is identical to
+FLID.

Write syntax:

+FCIG="<local ID string>"

Valid value:

20-character ASCII string

Default value:

Empty

5.3.8

+FLPL - Indicate a Document for Polling

This command allows setting up an answering modem to know that it has a document available for polling. This allows a
calling modem to receive this fax from the answerer. The syntax is:

AT+FLPL=?
0,1

OK
AT+FLPL=1

OK
AT+FLPL?
1

5.3.9

+FSPL - Enable Polling

This command allows setting up an originating modem to be able to request to receive a document from a polled station. The
syntax is:

AT+FSPL=?
0,1

OK
AT+FSPL=1

OK
AT+FSPL?
1