Comtrol AT Commands for SmartACFL User Manual

Page 140

Advertising
background image

Command Reference Manual

5-18

Conexant

100722A

5.5.4

+FLID= - Local ID String

Write syntax:

+FLID="<local ID string>"

Valid value:

20-character ASCII string

Default value:

Empty

If FLID is not a null string, it generates a TSI or CSI frame. Table 3/T.30 includes digits 0-9, “+” and space.

If the DCE supports use of Table 3/T.30 only, the response to a +FLID=? command is “(20) (32, 43, 48-57).” If the DCE
supports printable ASCII <, the response is: “(20) (32-127)<CRLF>.” The first “(20)” represents string length: the second
(character values) field reports supported string values.

1. The string is saved in RAM.

2. Non-numeric characters are not filtered out.

3. The string is right justified.

5.5.5

+FCR - Capability to Receive

Write syntax:

+FCR=<value>

Valid values:

0 or 1

Default value:

0

+FCR=0 indicates that the DCE will not receive message data. This can be used when the DTE has insufficient storage. The
DCE can send and can be polled for a file.

+FCR is sampled in CCITT T.30 Phase A and Phase D.

5.5.6

+FPTS= - Page Transfer Status

Write Syntax:

+FPTS=<ppr>

Valid values:

1, 2, 3, 4, 5

Default value:

0

The +FPTS parameter contains a value representing the post page response, including copy quality and related end-of-page
status. These values correspond to post page response messages defined in T.30. The receiving DCE sets this parameter
after it receives a page of Phase C data. The transmitting DCE sets this parameter with the status reported by the receiving
station. The DTE may inspect or modify this parameter.

The set of <ppr> values is defined in Table 5-4. These values are also reported in the +FPTS response to the +FDR
command.

5.5.7

+FCQ - Copy Quality Checking

Write syntax:

+FCQ=<value>

Valid values:

0

Default value:

0

This parameter controls Copy Quality checking by a receiving facsimile DCE.

The DCE returns +FCQ=0 which indicates the DCE does no quality checking. The DCE will generate Copy Quality OK (MCF)
responses to complete pages, and set +FPTS=1.

5.5.8

+FPHCTO - DTE Phase C Response Time-out

Write syntax:

+FPHCTO=<value>

Valid values:

0 - 255, 100 millisecond units.

Default value:

30

The +FPHCTO command determines how long the DCE will wait for a command after reaching the end of data when
transmitting in Phase C. When this time-out is reached, the DCE assumes there are no more pages and no documents to
send. It then sends the T.30 EOP response to the remote device.