Conexant – Comtrol AT Commands for SmartACFL User Manual

Page 112

Advertising
background image

Command Reference Manual

4-6

Conexant

100722A

4.2.2.5 +FTM - Transmit Facsimile
This command causes the modem to transmit data using the modulation defined below. When a valid <mod> value is
entered, the modem transmits the proper training sequence in the selected mode, followed by constant 1 bits until data is
received from the DTE. The modem also returns the CONNECT result code at the beginning of the training sequence.

Syntax

+FTM=<mod>

Defined Values

<mod>

Decimal number corresponding to the selected modulation mode and data rates shown in Table
4-2.

Table 4-2. Fax Class 1 and Fax Class 1.0 Modulation Modes and Rates

<mod>

Modulation

Training

Modulation Mode and Rate

3

V.21

300 bps

24

V.27 ter

2400 bps

48

V.27 ter

4800 bps

72

V.29

7200 bps

73

V.17

long

7200 bps long

74

V.17

short

7200 bps short

96

V.29

9600 bps

97

V.17

long

9600 bps long

98

V.17

short

9600 bps short

121

V.17

long

12000 bps long

122

V.17

short

12000 bps short

145

V.17

long

14400 bps long

146

V.17

short

14400 bps short

Result Codes

CONNECT

Reported when the modems begins the training sequence after receipt of a valid <mod> value.

ERROR

If the modem’s transmit buffer becomes empty and the last transmitted character is NUL (00), the
modem continues to transmit NULs until the DTE sends more data or five seconds elapses. After
five seconds elapse with a empty transmit buffer, the modem will turn off the transmit carrier,
return to the command state, and report the ERROR result code.

OK

If the modem’s transmit buffer becomes empty and the last transmitted character is was not NUL,
the modem will turn off the transmit carrier, return to the command state, and report the OK result
code.

Reporting Current or Selected Values
Command: +FTM?
Response:

+FTM: <mod>

Example:

+FTM: 98

For V.17 9600 bps.

Reporting Supported Range of Parameter Values
Command: +FTM=?
Response:

+FTM: (<mod> range)

Example:

+FTM: 3,24,48,72,73,74,96,97,98,121,122,145,146

Advertising