Comtrol AT Commands for SmartACFL User Manual

Page 29

Advertising
background image

Command Reference Manual

100722A

Conexant

3-9

3.2.1.14 &F - Restore Factory Configuration (Profile)
The modem loads the factory default configuration (profile). The factory defaults are identified for each command and in the
S-Parameter descriptions. A configuration (profile) consists of a subset of S-Parameters.

Syntax

&F[<value>]

Defined Values

<value>

Decimal number corresponding to the selected configuration.

0

Restore factory configuration 0.

1

Restore factory configuration 1.

Result Codes

OK
ERROR

If the modem is connected.

3.2.1.15 &T - Local Analog Loopback Test
The modem will perform the local analog loopback test if &T1 is selected. The test can be run only when in an asynchronous
operation in non-error-correction mode (normal), e.g., AT&Q6. To terminate the test in progress, the escape sequence must
be entered first (see Section 3.1.1).

Syntax

&T[<value>]

Defined Values

<value>

Decimal number corresponding to the selected option.

0

Terminates test in progress. Clears S16.

1

Initiates local analog loopback, V.54 Loop 3. Sets S16 bit 0. If a connection exists
when this command is issued, the modem hangs up. The CONNECT XXXX
message is displayed upon the start of the test.

3.2.1.16 &Y - Designate a Default Reset Profile
This command selects which user profile will be used after a hard reset.

Syntax

&Y<value>

Defined Values

<value>

Decimal number corresponding to the selected profile.

0

The modem will use profile 0.

1

The modem will use profile 1.

Result Codes

OK

<value> = 0 to 1.

ERROR

If <value> > 1, or if NVRAM is not installed or is not operational.

Advertising
This manual is related to the following products: