Command Reference Manual

100722A

Conexant

5-19

5.5.9

+FAXERR - T.30 Session Error Report

Read syntax:

+FAXERR= <table value>, read only

Valid values:

0 - 255, see Table 5-5 for meaning

This read-only parameter indicates the cause of the hangup. Table 5-5 shows the valid values for this parameter as well as
the meaning of the each value. +FAXERR is set by the DCE at the conclusion of a fax session. The DCE resets +FAXERR to
0 at the beginning of Phase A off-hook time.

5.5.10

+FBOR - Data Bit Order

Write syntax:

+FBOR=<value>

Valid values:

0, 1, 2, or 3

Default value:

0

This parameter controls the mapping between PSTN facsimile data and the DTE-DCE link. There are two choices:

Direct: The first bit transferred to each byte on the DTE-DCE link is the first bit transferred on the PSTN data carrier.

Reversed: The last bit transferred of each byte on the DTE-DCE link is the first bit transferred on the PSTN data carrier.

There are two data types to control:

This command controls Phase C data (T.4 encoded data) transferred during execution of +FDT or +FDR commands.

The following two codes are supported:

+FBOR=0 or 2

Selects direct bit order for Phase C data.

+FBOR=1 or 3

Selects reversed bit order for Phase C data.

This parameter does not affect the bit order of control characters generated by the DCE.

5.5.11

+FAA - Answer Parameter

Write syntax:

+FAA=<value>

Valid values:

0 or 1

Default value:

0

+FAA=0

Constrains the DCE to answer as set by +FCLASS.

+FAA=1

Indicates that the DCE can answer and automatically determine whether to answer as a Class 2
facsimile DCE or as a data modem. If the DCE automatically switches, it modifies FCLASS
appropriately.

Fax adaptive answer operates only when +FCLASS=0.

Class 2 adaptive answer is implemented as follows:

First, a data mode handshake is attempted. If the DCE has been configured for automode detection (using the +MS
command), the DCE may try several protocols before terminating attempts to make a data mode connection. This can take as
long as 6-8 seconds.

If the data mode connection attempt fails, a facsimile Class 2 connection is assumed. When a connection is made as a result
of the adaptive answer, the DCE issues the DATA or FAX result code before the CONNECT or +FCON message to inform the
DTE of the connection type. After making a Class 2 connection, the DCE stays on-line rather than going into the command
mode as with a Class 1 connection.