3.3.3.15 S16 - Test Mode Bit Mapped Options Status
S16 indicates the test in progress status.

Default: 0

Bit 0

Local analog loopback

0 =

Disabled (Default.)

1 =

Enabled (&T1)

Bits 1-7

Not used

3.3.3.16 S19 - Reserved
S19 is supported for backwards compatibility only. No value can be written. Responds with default value.

Range:

None

Default: 0

3.3.3.17 S20 - Reserved
S20 is supported for backwards compatibility only. No value can be written. Responds with default value.

Range:

None

Default: 0

3.3.3.18 S21 - V.24/General Bit Mapped Options Status
S21 indicates the status of command options.

Default: 52 (34h) (00110100b)

Bits 0 - 1

Reserved (0)

Bit 2

CTS behavior (&Rn)

0 =

CTS tracks RTS (&R0)

1 =

CTS always on (&R1) (Default.)

Bits 3-4

DTR behavior (&Dn)

0 =

&D0 selected

1 =

&D1 selected

2 =

&D2 selected (Default.)

3 =

&D3 selected

Bit 5

RLSD (DCD) behavior (&Cn)

0 =

&C0 selected

1 =

&C1 selected (Default.)

Bit 6

DSR behavior (&Sn)

0 =

&S0 selected (Default.)

1 =

&S1 selected

Bit 7

Long space disconnect (Yn)

0 =

Y0 (Default.)

1 =

Y1