Doors.NET Reference Manual

- 339 -

l

Poll Delay (ms)

- the delay between communication polls (in milliseconds)

l

Retry Count

- the number of retries before a communication failure is reported

l

Offline Timeout (ms)

- the amount of time in milliseconds for the controller to con-

sider itself offline with the host

l

Baud Rate to Panels

- the baud rate to the downstream field devices

Communications Interface

l

Enable Communications

- lists if communications to this panel are enabled

l

Bus

- lists the bus number to which this panel is connected

Monitoring

l

Device Type

- select a device type identifier which is used in event monitoring, sort-

ing, and operator assignments

l

Primary Priority

- the priority for this object. The range is 0 to 255 with 0 being the

highest priority.

l

Use This Filter

- select a custom filter which controls which events are displayed,

acknowledged, or recorded (in the case of event video recording)

l

Require Acknowledgement

- Enables Operator acknowledgement for this object.

The type of event(s) to be acknowledged is determined by the filter.

l

Enable Sounds

- enables Sound alerts for this object. The sounds are played as a

result of the state of an alert and are configured through the Device Types.

l

Global Trigger

- select an event trigger that will be tested when this panel creates

an event - if the event matches the trigger, the trigger will activate

Options

l

Download Cardholders with no Access Rights

- This option downloads each card-

holder regardless of access rights. Otherwise, only cardholders that have access
rights to a door on this controller are sent

l

Enable Area Control

- This option enables area control on this controller. Area Con-

trol allows doors to be grouped together for counting or Global Anti-Passback pur-
poses.