Altera External Memory PHY Interface User Manual

Page 73

Advertising
background image

Chapter 4: Support for Arria GX, HardCopy II, Stratix II, and Stratix II GX Devices

4–5

DDR2/DDR SDRAM

© January 2010

Altera Corporation

External Memory PHY Interface (ALTMEMPHY) (nonAFI) Megafunction User Guide

Table 4–1

shows the clock outputs that Arria GX, HardCopy II, Stratix II and

Stratix II GX devices use.

Table 4–1. DDR2/DDR SDRAM Clocking in Arria GX, HardCopy II, Stratix II, and Stratix II GX Devices (Part 1 of 2)

Design

Rate

Clock Name

Postscale

Counter

Phase

(Degrees)

Clock Rate

Clock

Network Type

Notes

Half-rate

phy_clk_1x

and

aux_half_rate_

clk

C0

0

Half-Rate

Global

The only clock that is
made available on the user
interface of the
ALTMEMPHY
megafunction. This clock
also feeds into a divider
circuit to provide the PLL
scan_clk

signal (for

reconfiguration) that must
be lower than 100 MHz.

mem_clk_2x

and

aux_full_

rate_clk

C1

0

Full-Rate

Global

This clock is for clocking
DQS and as a reference
clock for the memory
devices.

Full rate

aux_half_rate_

clk

C0

0

Half-Rate

Global

The only clock that is
made available on the user
interface of the
ALTMEMPHY
megafunction. This clock
also feeds into a divider
circuit to provide the PLL
scan_clk

signal (for

reconfiguration) that must
be lower than 100 MHz.

phy_clk_1x

(1)

and

mem_clk_2x

and

aux_full_

rate_clk

C1

0

Full-Rate

Global

This clock is for clocking
DQS and as a reference
clock for the memory
devices.

Half-rate
and full rate

write_clk_2x

C2

–90

Full-Rate

Global

This clock is for clocking
the data out of the DDR
I/O (DDIO) pins in
advance of the DQS strobe
(or equivalent). As a
result, its phase leads that
of the mem_clk_2x by
90°.

Advertising