Chapter 8 - Power Distribution Unit

124

Adept Python Modules User’s Guide, Rev. E

8.4

PDU3 Connectors and Indicators

1.

Status indicator LEDs:
24 V

- ON indicates 24 VDC power supply in the

PDU3 is working
AMP

- ON indicates 24 VDC to MB-10 is operating

AUX

- ON indicates 24 VDC to AUX is operating

CH1/2 -

E-Stop channel 1 or 2 voltage within range

ES1

- ON indicates E-Stop Relay 1 is on

ES2

- ON indicates E-Stop Relay 2 is on

Note

: both relays must be on to enable AC power

to MB-10 amps.

2. AMP DC RESET

button - for resetting the internal

circuit breaker on the 24 VDC supply to MB-10
amps

AUX DC RESET

button - for resetting the internal

circuit breaker on the 24 VDC supply to AUX

NOTE:

Do not push reset buttons while the system

is operating because it will cause 24 V power to
cycle and will require restarting the system.

3. XDCS

- connector for 24 VDC cable to MB-10 amps

This cable provides:
- 24 VDC to MB-10 amps
- 24 VDC to Aux/IO Blox
- Auto/Manual signals for Manual mode

operation

4. XSLV1/2

- (1) connection to host controller E-Stop

(2) connection for terminator plug
Note

: XSLV1 and 2 are interchangeable. The

terminator plug must be installed for the system to
operate.

5. AC PWR AMP

- connector for switched AC power

cable to MB-10 amps.

6. Circuit Breaker

- 6 Amp circuit breaker for

switched AC power going to MB-10 amps. Press
the button in to reset it if it has tripped.

7. AC PWR IN

- connector, fuses, and On/Off switch

for incoming AC power to PDU3.

NOTE:

200-240 VAC required for Python systems.