• Manually move the slider on each axis in the system through the full range of

motion to ensure there are no mechanical problems with the sliders or internal
bearings. This also helps verify that all cable tubes are installed correctly and there
is no binding or stress on any cables or connectors. If you have a module with a
brake, you have to wait until you have 24 V power turned on to use the Brake
Release button to move the module.

Power Checks

Verify that the SmartController and the PDU3 are correctly connected to their power
supplies.

1. Make sure that power is shut off to both the SmartController and the PDU3.

2. Verify that 24 VDC power is connected to the SmartController.

3. Verify that 220 VAC single-phase power is connected to the PDU3.

4. Verify that all voltages and voltage frequencies are within range.

Cable Installation Checks

Make sure that all cables are correctly installed. Refer to

Figure 7-1 on page 118

for the

system cable diagram.

1. Check all cable connections to the SmartController and make sure they are secure.

2. Check all connections on the PDU3 to make sure they are secure.

3. Check the cable connections at each MB-10 in the system to ensure integrity of

signal connections, especially encoder feedback, and to ensure the integrity of the
ground shields and other

EMC

measures.

4. Check the cable connection between the SmartController and

t

he Front Panel.

Verify that the plug is latched on both ends of the cable.

5. If you are using the AdeptWindows PC user interface, use a shielded Ethernet

cable from the hub (or server) to the shielded RJ45 connector on the
SmartController. Unshielded cables will degrade the integrity of the
AdeptWindows PC link, particularly when power is applied to the robot or
mechanism. Use “straight” cables to a hub or a “crossover” cable to a stand-alone
PC.

User-Supplied Safety Equipment Checks

Verify that all user-supplied safety equipment and E-Stop circuits are installed correctly.
See the

Adept SmartController User’s Guide

for information on these topics.