Electrical Installation

If there is any reason to suspect large voltage fluctuations, place a recorder on the line for at least one
phase of the power for one week while the display operates normally. Contact Daktronics Customer
Service with respect to this recording.

Display brightness and lamp life are generally determined assuming an average incoming line voltage
of 120 volts AC at 60 hertz. If the line voltage varies from that value, it will affect both lamp life and
brightness. Lamp life results will also vary with programming style and use of dimming mode.

§ Lamp life predictions are for lamps operating in a laboratory with continuous operation in a stable
temperature and mechanical environment. Actual values will differ from predicted life because of
switched operation, varying temperature, mechanical vibrations due to wind, traffic and sign service
and actual hours of operation. Data is that of the manufacturer.

Lamp Voltage/Lamp Life with 23 VAC Secondary (T-1109 XFMR)

120 V Only

5 V Buck

5 V Boost

Line

Volts

Lamp

Volts

Candle

Power

Lamp

Life

Hours

Lamp

Volts

Candle

Power

Lamp

Life

Hours

Lamp

Volts

Candle

Power

Lamp

Life

Hours

18.90

19.72 3.42 35022

18.90 2.95 59271

20.60 3.98 20250

108 20.10 3.66 27530

19.27 3.16 46578

21.00 4.26 15923

110 20.48 3.91 21740

19.64 3.37 36770

21.40 4.55 12577

112 20.87 4.17 17242

20.01 3.60 29155

21.80 4.86 9978

113 21.06 4.30 15380

20.19 3.71 16003

22.00 5.01 8902

114 21.25 4.44 13733

20.38 3.83 23215

22.20 5.18 7950

115 21.44 4.58 12275

20.56 3.96 20748

22.40 5.34 7107

116 21.63 4.73 10983

20.74 4.08 18561

22.60 5.51 6359

117 21.83 4.88 9836 20.93 4.21 16621

22.80 5.68 5696

118 22.02 5.03 8818 21.11 4.34 14899

23.00 5.86 5107

119 22.21 5.18 7912 21.30 4.48 13367

23.20 6.04 4583

120

22.40

5.34

7107

21.48

4.61

12004

23.40

6.22

4117

121 22.59 5.50 6389 21.66 4.75 10790

23.60 6.41 3701

122 22.78 5.67 5748 21.85 4.89 9708 23.80 6.60 3331

123 22.98 5.84 5177 22.03 5.04 8742 24.00 6.80 3000

124 23.17 6.01 4666 22.22 5.19 7878 24.20 7.00 2704

125 23.36 6.18 4210 22.40 5.34 7107 24.40 7.20 2440

126 23.55 6.36 3801 22.58 5.50 6416 24.60 7.41 2203

127 23.74 6.55 3435 22.77 5.65 5797 24.80 7.63 1991

128 23.93 6.73 3106 22.95 5.82 5242 25.00 7.84 1801

129 24.13 6.92 2811 23.14 5.98 4744 25.20 8.07 1630

130 24.32 7.12 2547 23.32 6.15 4297 25.40 8.29 1477


If the line voltage is near or above 125 volts or a longer lamp life is desired, contact Daktronics for
transformer adjustment.

Contact a local electrician or the local power company if line voltage is substantially above or below
normal.