Electrical Installation

3-5

3.4

Preparing the Display for Power & Signal Connection

Reference Drawings:

Shop Drawing, 7 or 8 High, 2 ½

˝

..........................................................Drawing A-114666

Shop Drawing, 16 High, 2 ½

˝

................................................................Drawing A-114667

Shop Drawing, 24 High, 2 ½

˝

................................................................Drawing A-114668


When connecting power and signal to this display it is necessary to access the following items.

Power termination panel.

Display controller (Venus 1500 controller or serial line interface)

Fan control enclosure – Venus 1500, 2V cabinet configurations only.


The shop drawings illustrate the locations of the above-listed items at the end of this section.
However, only one of the drawings is appropriate for this display. Use the following table to choose
the correct shop drawing.

If the display being installed is…

Consult shop drawing…

7 or 8 high display (all lengths)

Drawing A-114666

16 high display (all lengths)

Drawing A-114667

24 high display (all lengths)

Drawing A-114668


After locating the power termination panel and display controller on the shop drawing, complete the
following steps to ready the display for power and signal hook-up.

1. Remove the necessary lens/reflector assemblies to gain access to the termination panel and display

controller. Lens/reflector removal is addressed in Lens/Reflector Assemblies in Section 4.3.
Venus 1500 systems need only access the fan control enclosure if installing two displays together
in a 2V cabinet configuration. Venus 4600 systems do not need access to the fan control enclosure
regardless of cabinet configuration.

2. Remove the covers from the power termination panel, the display controller and, if needed, the fan

control enclosure.


Daktronics completes all internal power and signal wire routing and connecting prior to shipment.

3.5

Bringing Power to the Display

Reference Drawing:

Assy, Term Panel................................................................................ Drawing A-113974

Only qualified individuals should perform power routing and termination to the display. It is
the responsibility of the installer to ensure the installation will adequately meet local codes and
standards.

! Run power from the power distribution point to the termination panel of each display face.
! Run power separately to each display face.
! This power is run through conduit according to national and local electrical codes.
! Use the knockouts in the back sheet located near the termination panel for the conduit entrance

point. This area is marked with a label (“Recommended Pwr & Sig Entrance Location”).

! Power cannot route through the display. Do not use the support conduit, located inside the

display, for power routing.