T1-04: motor rated current, T1-05: motor base frequency, T1-06: number of motor poles – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 116: T1-07: motor base speed, T1-08: pg number of pulses per revolution, T1-09: motor no-load current, 5 auto-tuning

Advertising
background image

4.5 Auto-Tuning

116

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

T1-04: Motor Rated Current

Sets the motor rated current according to the motor nameplate value. Set the motor rated current between 50% and 100%
of the drive rated current for optimal performance in OLV or CLV. Enter the current at the motor base speed.

T1-05: Motor Base Frequency

Sets the motor rated frequency according to the motor nameplate value. If a motor with an extended speed range is used
or if the motor is used in the field weakening area, enter the maximum frequency to E1-04 (E3-04 for motor 2) after Auto-
Tuning is complete.

T1-06: Number of Motor Poles

Sets the number of motor poles according to the motor nameplate value.

T1-07: Motor Base Speed

Sets the motor rated speed according to the motor nameplate value. If a motor with an extended speed range is used or if
the motor is used in the field weakening area, enter the speed at base frequency to T1-07.

T1-08: PG Number of Pulses Per Revolution

Sets the number of pulses from the PG encoder. Set the actual number of pulses for one full motor rotation.

Note: T1-08 will only be displayed in CLV.

T1-09: Motor No-Load Current

Sets the no-load current for the motor. The default setting displayed is no-load current automatically calculated from the
output power set in T1-02 and the motor rated current set to T1-04. Enter the data listed on the motor test report. Leave
this data at the default setting if the motor test report is not available.

No.

Parameter Name

Setting Range

Default

T1-04

Motor Rated Current

10 to 200% of drive rated current

Depending on o2-04

No.

Parameter Name

Setting Range

Default

T1-05

Motor Base Frequency

0.0 to 120.0 Hz

60.0 Hz

No.

Parameter Name

Setting Range

Default

T1-06

Number of Motor Poles

2 to 48

4

No.

Parameter Name

Setting Range

Default

T1-07

Motor Base Speed

0 to 24000 r/min

1750 r/min

No.

Parameter Name

Setting Range

Default

T1-08

PG Number of Pulses Per Revolution

0 to 60000 ppr

1024 ppr

No.

<1> The display resolution depends on the rated output power of the drive. Models 2A0018 to 2A0041 and 4A0009 to 4A0023 display values in

0.01 A units, while models 2A0059 to 2A0432 and 4A0030 to 4A0260 display values in 0.1 A units.

Parameter Name

Setting Range

Default

T1-09

<1>

Motor No-Load Current

0 to [T1-04] A

(Max: 0 to 2999.9)

Advertising