E5: pm motor settings, E4-05: motor 2 line-to-line resistance, E4-06: motor 2 leakage inductance – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 184: E5-02: motor rated power, E5-03: motor rated current, E5-04: number of motor poles, E5-05: motor stator resistance (single phase), 5 e: motor parameters

Advertising
background image

5.5 E: Motor Parameters

184

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

E4-05: Motor 2 Line-to-Line Resistance

Sets the line-to-line resistance for the motor 2 stator winding. If Auto-Tuning completes successfully, this value is
automatically calculated. Enter this value as line-to-line and not for each motor phase.

Refer to E2-05: Motor Line-to-

Line Resistance on page 180

to manually enter this parameter setting.

E4-06: Motor 2 Leakage Inductance

Sets the voltage drop due to motor leakage inductance as a percentage of rated voltage of motor 2. This value is
automatically set during Auto-Tuning (Rotational Auto-Tuning and Stationary Auto-Tuning 1, 2).

E5: PM Motor Settings

These parameters set the motor data of a PM motor.

For PM motors, Auto-Tuning can be performed. If motor data is known, it can also be entered manually.

Note: 1. E5-†† parameters are visible only when a PM motor control mode is selected (A1-02 = 7).

2. E5-†† parameters are not reset when the drive is initialized using parameter A1-03.

E5-02: Motor Rated Power

Sets the rated power of the motor. Determined by the value set to T2-04 during the Auto-Tuning process.

E5-03: Motor Rated Current

Sets the motor rated current in amps. Automatically set when the value is entered to T2-06 during Auto-Tuning.

Note: The display resolution depends on the rated output power of the drive. Models 2A0018 to 2A0041 and 4A0009 to 4A0023 display

values in 0.01 A units, while models 2A0059 to 2A0432 and 4A0030 to 4A0260 display values in 0.1 A units.

E5-04: Number of Motor Poles

Sets the number of motor poles. Automatically set when the value is entered to T2-08 during Auto-Tuning.

E5-05: Motor Stator Resistance (Single Phase)

Sets the resistance for one motor phase. Do not enter the line-to-line resistance into E5-05 when measuring the resistance
manually.

No.

Parameter Name

Setting Range

Default

E4-05

Motor 2 Line-to-Line Resistance

0.000 to 65.000

Ω

Determined by o2-04

No.

Parameter Name

Setting Range

Default

E4-06

Motor 2 Leakage Inductance

0.0 to 40.0%

Determined by o2-04

No.

Parameter Name

Setting Range

Default

E5-02

Motor Rated Power

0.10 to 650.00 kW

Determined by o2-04

No.

Parameter Name

Setting Range

Default

E5-03

Motor Rated Current

10 to 200% of drive rated current

Determined by o2-04

No.

<1> When PG-E3 option connected: Max. setting = 48.

Parameter Name

Setting Range

Default

E5-04

Number of Motor Poles

2 to 120

<1>

12

No.

Parameter Name

Setting Range

Default

E5-05

Motor Stator Resistance (Single Phase)

0.000 to 65.000

Ω

Determined by o2-04

Advertising