5.6 F: Option Settings

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

189

P

a

ra

me

te

r De

ta

ils

5

F1-52: Communication Speed of Serial Encoder Selection

Selects the speed for serial communication between a PG-F3 option card and serial encoder.

Setting 0: 1M bps / 9600 bps (EnDat 2.2/22 / Hiperface)
Setting 1: 500k bps / 19200 bps (EnDat 2.2/22 / Hiperface)
Setting 2: 1M bps / 38400 bps (EnDat 2.2/22 / Hiperface)
Setting 3: 1M bps / 38400 bps (EnDat 2.2/22 / Hiperface)

F1-63: PG-E3 R Track Selection

Enables or disables the R phase when a PG-E3 option card is used.

Setting 0: Disabled

The R track is not used. The rotor magnet position is calculated from the C and D track signal only.

Setting 1: Enabled

The R track signals are used to determine the rotor magnet position.

F1-66 to F1-81: Encoder Adjust 1 to 16

Sets encoder offsets 1 to 16 for the PG-E3 option card. These parameters are automatically set by the execution of Auto-
Tuning of PG-E3 encoder characteristics.

F3: Digital Input Card Settings

These parameters set up the drive for operation with the option card DI-A3. Refer to the instruction manual packaged
with the option card for specific details on installation, wiring, input signal level selection, and parameter setup.

F3-01: DI-A3 Option Card Input Selection

Determines the type of input for digital option card DI-A3 when o1-03 is set to 0 or 1.

Setting 0: BCD, 1% units
Setting 1: BCD, 0.1% units
Setting 2: BCD, 0.01% units
Setting 3: BCD, 1 Hz units
Setting 4: BCD, 0.1 Hz units
Setting 5: BCD, 0.01 Hz units
Setting 6: BCD, special setting (5 digit input), 0.02 Hz units
Setting 7: Binary

The unit and the setting range are determined by F3-03.

F3-03 = 0: 255/100% (-255 to +255)

F3-03 = 1: 4095/100% (-4095 to +4095)

F3-03 = 2: 30000/100% (-33000 to +33000)

No.

Parameter Name

Setting Range

Default

F1-52

Communication Speed of Serial Encoder Selection

0 to 3

0

No.

Parameter Name

Setting Range

Default

F1-63

PG-E3 R Track Selection

0, 1

0

No.

Parameter Name

Setting Range

Default

F1-66 to F1-81

Enoder Adjust 1 to 16

0 to FFFF

0

No.

Parameter Name

Setting Range

Default

F3-01

DI-A3 Option Card Input Selection

0 to 7

0