2 using the led monitor/digital operator, Led monitor jvop-184, Led display examples – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 89

Advertising
background image

4.2 Using the LED Monitor/Digital Operator

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

89

St

ar

t-

U

p

Pr

og

ra

m

m

in

g

&

Op

er

at

io

n

4

4.2 Using the LED Monitor/Digital Operator

LED Monitor JVOP-184 shows information about drive status including faults and alarms; optional digital operator
JVOP-180 can be used to adjust parameters as required.

LED Monitor JVOP-184

The LED monitor indicates operation status by combinations of the LEDs (LIGHT/BLINK/OFF) at RUN, DS1, and DS2.

Figure 4.1

Figure 4.1 LED Monitor Component Names

LED Display Examples

Normal Operation

Figure 4.2

shows the LED display when the drive is ready and no FWD/REV signal is active.

Figure 4.2

Figure 4.2 Normal Operation LED

Alarm

Figure 4.3

shows the LED display when a minor fault occurs.

Refer to Troubleshooting on page 267

and take

appropriate countermeasures.

Figure 4.3

Figure 4.3 Alarm LED

Fault

Figure 4.4

shows the LED display when an oV or UV fault has occurred.

Figure 4.4

Figure 4.4 Fault LED

A – PWR LED (Red)

E – DS2 LED (Green)

B – Drive Status Indications

F – DS1 LED (Green)

C – Alarm Indications

G – RUN LED (Green)

D – Fault Indications

PWR

LED MONITOR JVOP-184

RUN

DS1

DS2

RUN DS1 DS2

STATUS

READY
RUN
ALARM(RUN)
PGOH,LT
BB,HBB
EF,SE

Other Fault

OV,UV
OH,OL
OC,GF,SC,PGO
CPF,OFA,OFB,OFC

:LIGHT

:BLINK

:LIGHT OFF

A

G

F
E

B

C

D

RUN

DS1

DS2

POWER

RUN

DS1

DS2

POWER

RUN

DS1

DS2

POWER