B.3 Parameter Table

402

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

T: Motor Tuning

Enter data into the following parameters to tune the motor and drive for optimal performance.

T1: Induction Motor Auto-Tuning

S6-15

(6BBH)

Speed Reference Loss Detection

Enabled or disables detection for speed reference missing (FrL).
0: Disabled
1: Enabled

Default: 1
Min: 0
Max: 1

263

S6-16

(6BCH)

Restart after Baseblock Selection

0: No restart after Baseblock/Safe Torque-Off
1: Restart after Baseblock/Safe Torque-Off

Default: 0
Min: 0
Max: 1

263

<1> Default setting value is determined by the digital operator display unit selection (o1-03). The default is normally 1.5 m/s

2

, but when o1-03 = 6,

the default becomes 5.0 ft/s

2

(Setting Range: 0.0 to 50.0 ft/s

2

).

No. (Addr.)

Name

Description

Setting

Page

T1-01

(701H)

<4> Default setting value varies by the drive model (o2-04).

<5> Default setting is determined by the control mode (A1-02).

<9> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.

<10> The display resolution depends on the rated output power of the drive. Models 2A0018 to 2A0041 and 4A0009 to 4A0023 display values in

0.01 A units, while models 2A0059 to 2A0432 and 4A0030 to 4A0260 display values in 0.1 A units.

<18> The variety of Auto-Tuning methods depends on the control mode setting. V/f Control allows T1-01 to be set to 2 or 3, while vector control

modes (OLV and CLV) allow T1-01 to be set to 0 through 4.

Auto-Tuning Mode Selection

0: Rotational Auto-Tuning
1: Stationary Auto-Tuning 1
2: Stationary Auto-Tuning for Line-to-Line Resistance
4: Stationary Auto-Tuning 2

Default: 0

<5>

Min: 0
Max: 4

<18>

115

T1-02

(702H)

Motor Rated Power

Sets the motor rated power as specified on the motor nameplate.
Note: Use the following formula to convert horsepower into kilowatts: kW = HP

× 0.746.

Default:

<4>

Min: 0.00 kW
Max: 650.00 kW

115

T1-03

(703H)

Motor Rated Voltage

Sets the motor rated voltage as specified on the motor nameplate.

Default: 200.0 V

<9>

Min: 0.0 V
Max: 255.0 V

<9>

115

T1-04

(704H)

Motor Rated Current

Sets the motor rated current as specified on the motor nameplate.

Default:

<4>

Min: 10% of drive rated
current
Max: 200% of drive
rated current

<10>

116

T1-05

(705H)

Motor Base Frequency

Sets the rated frequency of the motor as specified on the motor nameplate.

Default: 50.0 Hz
Min: 0.0 Hz
Max: 200.0 Hz

116

T1-06

(706H)

Number of Motor Poles

Sets the number of motor poles as specified on the motor nameplate.

Default: 4

Min: 2
Max: 48

116

T1-07

(707H)

Motor Base Speed

Sets the rated speed of the motor as specified on the motor nameplate.

Default: 1450 r/min
Min: 0 r/min
Max: 24000 r/min

116

T1-08

(708H)

Encoder Resolution (pulses per
revolution)

Set the number of pulses per revolution for the PG being used (pulse generator or encoder).

Default: 1024 ppr
Min: 0 ppr
Max: 60000 ppr

116

T1-09

(709H)

Motor No-Load Current

(Stationary Auto-Tuning 1 and 2)

Sets the no-load current for the motor.
After setting the motor capacity to T1-02 and the motor rated current to T1-04, this parameter
will automatically display the no-load current for a standard 4 pole Yaskawa motor. Enter the
no-load current as indicated on the motor test report.

Default: –

Min: 0 A
Max: Up to T1-04

<10>

116

T1-10

(70AH)

Motor Rated Slip

(Stationary Auto-Tuning 2)

Sets the motor rated slip.
After setting the motor capacity to T1-02, this parameter will automatically display the motor
slip for a standard 4 pole Yaskawa motor. Enter the motor slip as indicated on the motor test
report.

Default: –

Min: 0.00 Hz
Max: 20.00 Hz

117

No. (Addr.)

Name

Description

Setting

Page

All Modes

common

_

All Modes

common

_

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

Advertising