B.3 Parameter Table

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

405

Pa

ra

met

er

L

is

t

B

U1-11

(4AH)

Output Terminal Status

Displays the output terminal status.

No signal output
available

U1-12
(4BH)

Drive Status

Displays the drive operation status.

No signal output
available

U1-13
(4EH)

Terminal A1 Input Voltage

Displays the voltage input to terminal A1.

10 V: 100%

(-10 to +10 V)

0.1%

U1-14

(4FH)

Terminal A2 Input Voltage

Displays the voltage input to terminal A2.

10 V: 100%

(-10 to +10 V)

0.1%

U1-16

(53H)

Output Speed after Soft Start

Displays output speed with ramp time and jerk settings. Units determined by o1-03.

10 V: Max frequency

(-10 to +10 V)

0.01%

<31>

U1-17

(58H)

DI-A3 Option Card Input
Status

Displays the reference value input from the DI-A3 option card.
Display will appear in hexadecimal as determined by the digital card input selection in F3-01.
3FFFF: Set (1 bit) + sign (1 bit) + 16 bit

No signal output
available

U1-18

(61H)

oPE Fault Parameter

Displays the parameter number that caused the oPE02 or oPE08 (Operation error).

No signal output
available

U1-19

(66H)

MEMOBUS/Modbus Error
Code

Displays the contents of a MEMOBUS/Modbus error.

No signal output
available

No. (Addr.)

Name

Description

Analog Output

Level

Unit

Page

All Modes

common

_

U1 - 11= 00000000

Multi-Function
Digital Output
(terminal M1-M2)

Digital Output
(terminal M3-M4)

Digital Output
(terminal M5-M6)

Multi-Function

Multi-Function

Digital Output
(terminal P1-C1)

Multi-Function

Digital Output
(terminal P2-C2)

Multi-Function

Not Used

Fault Relay
(terminal MA-MC closed

MA-MC open)

1

1

1

1

1

1

YEA_c

o m -

All Modes

common

_

U1 - 12= 00000000

During run

During zero-speed

During down direction

During fault reset
signal input

During speed agree

Drive ready

During alarm
detection

During fault detection

1
1

1
1

1
1

1

1

YEAc

o m -

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

U1 - 19= 00000000

CRC Error

Data Length Error

Not Used

Parity Error

Overrun Error

Framing Error

Timed Out

Not Used

1
1

0
1
1
1
1
0

YEAco

mmon

Advertising