4.6 Setup Procedure for Elevator Applications

122

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

Setting d1-18 = 3

Allows seven speed references to be set using parameters d1-02 to d1-08. The drive starts with an Up or Down command,
and stops either when all three input terminals that set the speed reference are released, or when the Up/Down command
is released. When d1-18 = 0, parameters d1-19 through d1-23 will not be displayed.

Separate Speed Inputs (d1-18 = 1 or 2)

Six different speed settings (defined in the parameters d1-19 to d1-24 and d1-26) can be set and selected using four digital
inputs.

Speed Selection

When d1-18 = 1 or 2, multi-function digital inputs are preset as shown below:

Different speed settings can be selected depending on the assignment of the speed selection digital inputs (H1-††) as
shown in the table below.

Note: Parameters d1-19 through d1-26 are displayed only if d1-18 is set to 1 or 2.

Higher Speed has Priority and the Leveling Speed Input is Assigned (d1-18 = 1 and H1-†† = 53) (Default)

The higher speed has priority over the leveling speed. The leveling signal is disregarded as long as any other speed
selection input is active. The drive decelerates to the leveling speed (d1-26) when the selected speed reference signal is
removed.

Terminal

Parameter Number

Set Value

Details

S3

H1-03

50

Nominal speed (d1-19)

S5

H1-05

51

Intermediate speed

S6

H1-06

53

Leveling speed (d1-26)

Selected Speed

Leveling and Nominal Speed assigned

(H1-††

= 50 and H1-†† = 53)

0 = Off, 1 = On, A = 0 when d1-18 = 2 and no influence when d1-18=1, B = no influence, N/A = Not available

Leveling speed not assigned

(H1-††

53)

Nominal Speed not assigned

(H1-††

50)

50

51

52

53

50

51

52

51

52

53

Nominal Speed (d1-19)

1

0

0

A

1

0

0

0

0

0

Intermediate Speed 1 (d1-20)

0

1

0

A

0

1

0

1

0

0

Intermediate Speed 2 (d1-21)

1

1

1

A

1

1

1

N/A

N/A

N/A

Intermediate Speed 3 (d1-22)

0

1

1

A

0

1

1

1

1

0

Releveling Speed (d1-23)

0

0

1

A

0

0

1

0

1

0

Leveling Speed (d1-26)

0

0

0

1

0

0

0

B

B

B

Zero Speed

0

0

0

0

N/A

N/A

N/A

N/A

N/A

N/A

Up/Down Command

Leveling speed

Selected speed (other than leveling)

Speed

DC Injection/
Position lock

DC Injection/

Position lock

Input is set

No effect

Safe disable (terminals H1/H2 on)

and Baseblock off (H1-

= 8/9)