5.8 L: Protection Functions

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

231

P

a

ra

me

te

r De

ta

ils

5

L8-89: Current Monitoring Selection

Enables and disables the Current Monitoring function. When this parameter is set to 1 (Enabled), the current monitoring
level (L8-99) is added to the conditions required to turn off the Motor Contactor Feedback command at a stop.

Setting 0: Disabled
Setting 1: Enabled

L8-99: Current Monitoring Level

Sets the current monitoring level as a percentage of the drive's rated current. When the output current is equal to or below
the set level, the Motor Contactor Feedback command turns off. This parameter is also used to activate the Motor Current
Monitor (H2-…… = 5C).

No.

Parameter Name

Setting Range

Default

L8-89

Current Monitoring Selection

0, 1

0

No.

Parameter Name

Setting Range

Default

L8-99

Current Monitoring Level

0.0 to 50.0 %

10.0 %