D.2 UL Standards

450

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

2A0106

R/L1, S/L2, T/L3

70

(1/0)

6.0 to 50

(10 to 1/0)

M8

9 to 11

(79.7 to 97.4)

U/T1, V/T2, W/T3

70

(1/0)

6.0 to 50

(10 to 1/0)

–, +1

35 to 50

(2 to 1/0)

B1, B2

16 to 50

(6 to 1/0)

16

(6)

16 to 25

(6 to 4)

2A0144

R/L1, S/L2, T/L3

70

(2/0)

6.0 to 95

(10 to 3/0)

M10

18 to 23

(159 to 204)

U/T1, V/T2, W/T3

95

(3/0)

6.0 to 95

(10 to 3/0)

–, +1

50 to 70

(1/0 to 3/0)

B1, B2

25 to 70

(4 to 2/0)

25

(4)

25

(4)

M8

9 to 11

(79.7 to 97.4)

2A0181

R/L1, S/L2, T/L3

95

(4/0)

70 to 95

(1/0 to 4/0)

M10

18 to 23

(159 to 204)

U/T1, V/T2, W/T3

95

(4/0)

70 to 95

(1/0 to 4/0)

–, +1

50 to 95

(1 to 4/0)

+3

70 to 95

(1/0 to 4/0)

25

(4)

25 to 35

(4 to 2)

2A0225

R/L1, S/L2, T/L3

70

× 2P

(1/0

× 2P)

70 to 95

(1/0 to 4/0)

M10

18 to 23

(159 to 204)

U/T1, V/T2, W/T3

70

× 2P

(1/0

× 2P)

70 to 95

(1/0 to 4/0)

–, +1

50 to 95

(1 to 4/0)

+3

70 to 95

(1/0 to 4/0)

25

(4)

25 to 50

(4 to 1/0)

2A0269

R/L1, S/L2, T/L3

95

× 2P

(3/0

× 2P)

95 to 150

(3/0 to 300)

M12

32 to 40

(283 to 354)

U/T1, V/T2, W/T3

95

× 2P

(3/0

× 2P)

95 to 150

(3/0 to 300)

–, +1

95 to 150

(3/0 to 300)

+3

35 to 150

(2 to 300)

M10

18 to 23

(159 to 204)

35

(3)

35 to 150

(2 to 300)

M12

32 to 40

(283 to 354)

2A0354

R/L1, S/L2, T/L3

120

× 2P

(4/0

× 2P)

95 to 150

(3/0 to 300)

M12

32 to 40

(283 to 354)

U/T1, V/T2, W/T3

120

× 2P

(4/0

× 2P)

95 to 150

(3/0 to 300)

–, +1

95 to 150

(3/0 to 300)

+3

95 to 150

(3/0 to 300)

M10

18 to 23

(159 to 204)

35

(2)

35 to 150

(2 to 300)

M12

32 to 40

(283 to 354)

Drive Model

Terminal

Recommended

Wire Size

mm

2

(AWG, kcmil)

Wire Range

mm

2

(AWG, kcmil)

Screw

Size

Tightening Torque