B.3 Parameter Table

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

385

Pa

ra

met

er

L

is

t

B

A

Up/Down Command Source

Open: The Up/Down command is supplied by an external reference (set in b1-02).
Closed: Digital operator supplies the Up/Down command.

201

B

Torque Detection 1

Closed: An overtorque or undertorque situation has been detected.

202

E

Fault

Closed: Fault occurred. (excluding CPF00 and CPF01)

202

F

Not used (Through Mode)

Set this value when the terminal is not used or when using the terminal in the pass-through mode.

202

10

Minor Fault

Closed: An alarm has been triggered, or the IGBTs have reached 90% of their expected life span.

202

11

Fault Reset Command Active

Closed: The drive has received a reset command from the multi-function input terminals or from serial network, or the
digital operator’s RESET key has been pressed.

202

12

Timer Output

Closed: Timer output.

202

13

Speed Agree 2

Closed: When drive output frequency equals the speed reference ±L4-04.

202

14

User-set Speed Agree 2

Closed: When the drive output speed is equal to the value in L4-03 ±L4-04.

203

15

Speed Detection 3

Closed: When the drive output speed is less than or equal to the value in L4-03 ±L4-04.

203

16

Speed Detection 4

Closed: When the output speed is greater than or equal to the value in L4-03 ±L4-04.

204

18

Torque Detection 2

Closed: Overtorque or undertorque has been detected.

202

1A

During Down Direction

Closed: Drive is running in the down direction.

204

1B

During Baseblock 2 (N.C.)

Open: Drive has entered the baseblock state (no output voltage).

204

1C

Motor 2 Selection

Open: Motor 1 is selected
Closed: Motor 2 is selected

205

1D

During Regeneration

Closed: Motor is operated in regenerative mode.

205

1E

Reset Enabled

Closed: An automatic reset is performed

205

1F

Motor Overload Alarm (oL1)

Closed: oL1 is at 90% of its trip point or greater. An oH3 situation also triggers this alarm.

205

20

Drive Overheat Pre-alarm (oH)

Closed: Heatsink temperature exceeds the parameter L8-02 value.

205

2F

Maintenance Period

Closed: Cooling fan, electrolytic capacitors, IGBTs, or the soft charge bypass relay may require maintenance.

205

30

During Torque Limit

Closed: When the torque limit has been reached.

205

33

Within Position Lock Bandwidth

Closed: Position deviation is within the Position Lock Bandwidth.

205

H2 Multi-Function Digital Output Settings

H2-††

Setting

Function

Description

Page

common

_

All Modes

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

common

_

All Modes

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

All Modes

common

_

common

_

All Modes

All Modes

common

_

All Modes

common

_

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV