B.3 parameter table – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 379

Advertising
background image

B.3 Parameter Table

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

379

Pa

ra

met

er

L

is

t

B

F1-03

(382H)

Operation Selection at Overspeed
(oS)

0: Ramp to stop. Decelerate to stop using the deceleration ramp in C1-02.
1: Coast to stop.
2: Fast Stop. Decelerate to stop using the deceleration ramp in C1-09.
3: Alarm only.

Default: 1

Min: 0
Max: 3

186

F1-04

(383H)

Operation Selection at Deviation

0: Ramp to stop. Decelerate to stop using the deceleration ramp in C1-02.
1: Coast to stop.
2: Fast Stop. Decelerate to stop using the deceleration ramp in C1-09.
3: Alarm only.

Default: 3
Min: 0
Max: 3

186

F1-05

(384H)

Encoder 1 Rotation Direction
Selection

0: A phase leads B in up direction
1: B phase leads A in up direction

Default:

<1>

Min: 0
Max: 1

187

F1-06

(385H)

PG 1 Pulse Monitor Output
Division Ratio

Sets the division ratio for the pulse monitor used of the PG option card installed to connector
CN5-C. By setting “xyz”, the division ratio becomes = [(1 + x) / yz]. If only using the A pulse
for one track input, then the input ratio will be 1:1, regardless of what F1-06 is set to.

Default: 1

Min: 1
Max: 132

187

F1-08

(387H)

Overspeed Detection Level

Sets the overspeed detection level as a percentage of the maximum output frequency.

Default: 115%

Min: 0%
Max: 120%

186

F1-09

(388H)

Overspeed Detection Delay Time

Sets the time in seconds for an overspeed situation to trigger a fault (oS).

Default: 0.0 s

Min: 0.0 s
Max: 2.0 s

186

F1-10

(389H)

Excessive Speed Deviation
Detection Level

Sets the speed deviation detection level as a percentage of the maximum output frequency.

Default: 10%

Min: 0%
Max: 50%

186

F1-11

(38AH)

Excessive Speed Deviation
Detection Delay Time

Sets the time in seconds for a speed deviation situation to trigger a fault (dEv).

Default: 0.5 s

Min: 0.0 s
Max: 10.0 s

186

F1-14

(38DH)

PG Open-Circuit Detection Time

Sets the time required to trigger a PG Open fault (PGo).

Default: 2.0 s

Min: 0.0 s
Max: 10.0 s

186

F1-18

(3ADH)

dv3 Detection Selection

0: Disabled
n: Sets the number of dv3 situations that may be detected before triggering an actual dv3 fault.

Default: 10

Min: 0
Max: 10

187

F1-19

(3AEH)

dv4 Detection Selection

0: Disabled
n: Number of pulses that the A and B pulse are reversed that triggers dv4 detection.

Default: 128

Min: 0
Max: 5000

187

F1-20

(3B4H)

PG Option Card Disconnect
Detection 1

0: Disabled
1: Enabled

Default: 1

Min: 0
Max: 1

188

F1-29

(3BFH)

dEv Detection Condition Selection

Selects when DEV is active.
0: After speed reference, soft starter output and motor speed have matched once.
1: After speed reference and soft starter output have matched once.
2: Always during Run

Default: 2
Min: 0
Max: 2

188

F1-50

(3D2H)

Encoder Selection

Selects the encoder connected the PG-F3 option.
0: EnDat 2.1/01, 2.2/01 Serial Communication + Sin/Cos
1: EnDat 2.2/22 Serial Communication
2: Hiperface

Default: 0
Min: 0
Max: 2

188

F1-51

(3D3H)

PGoH Detection Level

Sets the level for detecting PG Hardware Fault (PGoH). Available when F1-20 = 1

Default: 80%
Min: 1%
Max: 100%

188

F1-52

(3D4H)

Communication Speed of Serial
Encoder Selection

Selects the communication speed between the PG-F3 option and serial encoder.
0: 1M bps/9600 bps
1: 500k bps/19200 bps
2: 1M bps/38400 bps
3: 1M bps/38400 bps

Default: 0
Min: 0
Max: 3

189

F1-63

(2DFH)

PG-E3 R Track Selection

0: Disabled
1: Enabled

Default: 0
Min: 0
Max: 1

189

No.(Addr.)

Name

Description

Setting

Page

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

Advertising