Speed selection using digital inputs (b1-01 = 0), 6 setup procedure for elevator applications – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 121

Advertising
background image

4.6 Setup Procedure for Elevator Applications

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

121

St

ar

t-

U

p

Pr

og

ra

m

m

in

g

&

Op

er

at

io

n

4

Travel Stop

The drive stops under the following conditions:

• The Up or Down command is removed.
• d1-18 is set to 1 or 2 and the Up/Down or Leveling Speed signal (H1-†† = 53) is removed.
• d1-18 is set to 3 and all speed inputs are removed.
• A fault occurs. The stopping method depends on the specific fault that occurred, in combination with certain parameter

settings.

• The Safe Disable inputs are opened or a Base Block signal is input. In this case, the brake is applied immediately and

the drive output shuts off.

Speed Selection Using Digital Inputs (b1-01 = 0)

Set parameter b1-01 = 0 to enable the speed selection using the drive digital inputs. Use parameter d1-18 to determine
different travel speeds selected by the digital inputs.

NOTICE: Always turn off the RUN command before changing the setting of parameters d1-18 (Speed Reference Selection Mode), b1-

01 (Speed Reference Selection), or H1-

††

(Multi-Function Digital Inputs). If the RUN command is on when changing any of these

settings, the motor may unexpectedly start running, and could result in injury.

Multi-Speed Inputs 1, 2 (d1-18 = 0 or 3)

Speed Selection

When d1-18 = 0 or 3, multi-function digital inputs are preset as shown below.

Different speed reference settings can be selected by combining the three digital inputs as shown in the table below.

Note: Parameters d1-19 through d1-26 are displayed only if d1-18 is set to 1 or 2.

Setting d1-18 = 0

Up to eight speed references can be set using parameters d1-01 to d1-08. The drive starts with an Up or Down command,
and stops when the Up or Down command is removed. When d1-18 = 0, parameters d1-19 through d1-23 will not be
displayed.

d1-18

Speed Selection

0 (default)

Multi-speed inputs 1, Speed references are set in d1-01 to d1-08

1

Separate speed inputs, Speed references are set in d1-19 to d1-24 and d1-26, Higher speed has priority

2

Separate speed inputs, Speed references are set in d1-19 to d1-24 and d1-26, Leveling speed has priority

3

Multi speed inputs 2, Speed references are set in d1-02 to d1-08, Stop if no speed selection input is enabled

Terminal

Parameter Number

Set Value

Details

S5

H1-05

3

Multi-Speed Reference 1

S6

H1-06

4

Multi-Speed Reference 2

S7

H1-07

5

Multi-Speed Reference 3

Digital Inputs

0 = Off, 1 = On

Selected Speed

Multi-Speed

Reference 1

Multi-Speed

Reference 2

Multi-Speed

Reference 3

d1-18 = 0

d1-18 = 3

0

0

0

Speed reference 1 (d1-01)

Stop

1

0

0

Speed reference 2 (d1-02 or terminal A1, A2 input value if H3-02 or H3-10 is set to 2)

0

1

0

Speed reference 3 (d1-03 or terminal A1, A2 input value if H3-02 or H3-10 is set to 3)

1

1

0

Speed reference 4 (d1-04)

0

0

1

Speed reference 5 (d1-05)

1

0

1

Speed reference 6 (d1-06)

0

1

1

Speed reference 7 (d1-07)

1

1

1

Speed reference 8 (d1-08)