5.11 S: Elevator Parameters

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

255

P

a

ra

me

te

r De

ta

ils

5

S4: Rescue Operation

Rescue Operation switches to a backup battery or some other UPS during a power outage.

Refer to Rescue Operation on

page 131

for details.

S4-01: Light Load Direction Search Selection

Enables and disables the Light Load Direction Search.

Setting 0: Disabled
Setting 1: Enabled
Setting 2: Enabled for motor 1 only

S4-02: Light Load Direction Search Method

Determines the method used to perform Light Load Direction Search.

Setting 0: Output current
Setting 1: Detect direction of regeneration

S4-03: Light Load Direction Search Time

Sets the time to perform Light Load Direction Search.

S4-04: Light Load Direction Search Speed Reference

Sets the speed reference to use during Light Load Direction Search.

S4-05: Rescue Operation Torque Limit

Sets the torque limit used during Rescue Operation.

S4-06: Rescue Operation Power Supply Selection

Specifies the type of backup power supply the drive should switch to when the power goes out.

Setting 0: Battery
Setting 1: UPS (single-phase)
Setting 2: UPS (three-phase)

No.

Parameter Name

Setting Range

Default

S4-01

Light Load Direction Search Selection

0 to 2

0

No.

Parameter Name

Setting Range

Default

S4-02

Light Load Direction Search Method

0 or 1

1

No.

Parameter Name

Setting Range

Default

S4-03

Light Load Direction Search Time

0.0 to 5.0 s

1.0 s

No.

Parameter Name

Setting Range

Default

S4-04

Light Load Direction Search Speed Reference

0.00 to 20.00%

Determined by A-02

No.

Parameter Name

Setting Range

Default

S4-05

Rescue Operation Torque Limit

0 to 300%

100%

No.

Parameter Name

Setting Range

Default

S4-06

Rescue Operation Power Supply Selection

0 to 2

0

Advertising