H: multi-function terminals, H1: multi-function digital inputs, B.3 parameter table – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 382

Advertising
background image

B.3 Parameter Table

382

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

H: Multi-Function Terminals

H parameters assign functions to the multi-function input and output terminals.

H1: Multi-Function Digital Inputs

F6-36

(3D1H)

CANopen Communication Speed

0: Auto-detection
1: 10 kbps
2: 20 kbps
3: 50 kbps
4: 125 kbps
5: 250 kbps
6: 500 kbps
7: 800 kbps
8: 1 Mbps

Default: 6

Min: 0
Max: 8

<1> Parameter setting value is not reset to the default value when the drive is initialized.

No.(Addr.)

Name

Description

Setting

Page

H1-03

(400H)

<19> With the speed reference priority d1-18 is set to 0 or 3, the default settings for parameters H1-03 to H1-07 governing input terminals S3 to S7

are: 24, 14, 3, 4, and 5 respectively. When d1-18 is set to 1 or 2, the default settings for H1-03 to H1-07 become 50, 54, 51, 53, and F

respectively.

Terminal S3 Function Selection

Assigns a function to the multi-function digital inputs.
Refer to page

382

to page

384

for a description of setting values.

Note: Unused terminals should be set to F.

Default:

<19>

Min: 3
Max: 79

193

H1-04

(401H)

Terminal S4 Function Selection

Default:

<19>

Min: 3
Max: 79

H1-05

(402H)

Terminal S5 Function Selection

Default:

<19>

Min: 3
Max: 79

H1-06

(403H)

Terminal S6 Function Selection

Default:

<19>

Min: 3
Max: 79

H1-07

(404H)

Terminal S7 Function Selection

Default:

<19>

Min: 3
Max: 79

H1-08

(405H)

Terminal S8 Function Selection

Default: F

Min: 3
Max: 79

H1 Multi-Function Digital Input Settings

H1-††

Setting

Function

Description

Page

3

Multi-Step Speed Reference 1

When input terminals are set to Multi-Step Speed References 1 through 3, switching combinations of those
terminals will create a multi-step speed sequence using the speed references set in d1-01 through d1-08.

193

4

Multi-Step Speed Reference 2

5

Multi-Step Speed Reference 3

6

Jog reference selection

Closed: Jog frequency reference (d1-17) selected.
The Jog frequency can be used when the speed reference selection is not assigned to input terminals (b1-01

≠ 1)

and the speed reference priority is set to use the multi-step speed reference (d1-18 = 0 or 3).

193

7

Accel/decel Ramp Selection 1

Used to switch between accel/decel ramp 1 (set in C1-01, C1-02) and accel/decel ramp 2 (set in C1-03, C1-04).

When combined with another input terminal set for "Accel/Decel ramp 2" (H1-†† = 1A), the drive can also
switch between accel/decel ramp 3 (set in C1-05, C1-06) and accel/decel ramp 4 (set in C1-07, C1-08).

194

8

Baseblock Command (N.O.)

Closed: No drive output

194

9

Baseblock Command (N.C.)

Open: No drive output

F

Not Used (Through Mode)

Select this setting when the terminal is not used or when using the terminal in the pass-through mode. The terminal
does not trigger a drive function but can be used as digital input for the controller the drive is connected to.

194

No.(Addr.)

Name

Description

Setting

Page

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

Advertising