Example 1 - Command Request Without Response only

For this example, the remote node is passing a timestamp event to be
transferred to the remote client connected to the ProLinx gateway.

The following block can be used for the first request.

Command Request Block

Word
Offset

Database
Address

Value Description

0

3000

100

Block ID1 - Command Request Without Response

1 3001

0 Block ID2 - Command Request With Response. Move

a value of 0 or any other value out of the 200 to 203
range since no data is requested back from the
gateway

2 to 10

3002 to 3010 Event Data

Timestamp event

99

3099

100

Block ID1 - Command Request Without Response

Command Response Block

Word Offset Database

Address

Value Description

0

3100

0

Block ID2 - Command Request With Response.

1

3101

100

Block ID1 - Command Request Without Response

2 to 98

3102 to 3198

Reserved

Reserved - no update

99

3199

0

Block ID2 - Command Request With Response.

In order to send another command request to pass another event, use the
following format:

Command Request Block

Word
Offset

Database
Address

Value Description

0

3000

101

Block ID1 - Command Request Without Response

1 3001

0 Block ID2 - Command Request With Response. Move

a value of 0 or any other value out of the 200 to 203
range since no data is requested back from the
gateway