5.2.6 Get Time Command Block

This functionality allows a remote node to retrieve the clock data from the
ProLinx gateway

Request Block

The following table describes the structure of the Get Time command block.

Start Word

End Word

Description

0

0

Block ID1 (Command Request Without Response)

1

1

200 or 201 = Get Time (Block ID2)

2 2

Year

3 3

Month

4 4

Day

5 5

Hour

6 6

Minutes

7

7

Seconds & milliseconds

8

98

Reserved for future use

99

99

Block ID1 (Command Request Without Response)

Response Block

Start Word

End Word

Description

0

0

200 or 201 = Get Time (Block ID2)

1

1

Block ID1 (Command Request Without Response)

2 2 Year

3 3 Month

4 4 Day

5 5 Hour

6 6 Minutes

7 7 Seconds

&

milliseconds

8

98

Reserved for future use

99

99

200 or 201 = Get Time (Block ID2)