System Exclusive Messages

Status

Data Byte

Status

F0H

iiH,ddH,...,eeH F7H

F0H:

Status of system exclusive message

ii= ID number:

This is the ID to recognize manufacturer of the exclusive
message (manufacturer ID).
The manufacturer ID of Roland is 41H.
The ID numbers of 7EH and 7FH are expansion of MIDI standards
and used as universal non-realtime message (7EH) of universal
realtime message (7FH).

dd,...,ee= data:

00H–7FH (0–127)

F7H:

EOX (end of exclusive)

7

Data Request 1 (RQ1)

This is the message to request of “send data” to the connected device. Specify data
type and amount using address and size. When this is received, the unit sends the
requested data as “Data Set 1 (DT1)” message in case the unit is in status where the
sending of data is possible and requested address and size are appropriate. If not, the
unit sends nothing.

Status

Data Byte Status

F0H

41H, 10H, 00H, 00H, 00H, 68H, 11H, aaH,

F7H

bbH, ccH, ssH, ttH, uuH, sum

Byte

Explanation

F0H

Exclusive Status

41H

Manufacturer ID (Roland)

10H

Device ID

00H

1st byte of model ID (V-8HD)

00H

2nd byte of model ID (V-8HD)

00H

3rd byte of model ID (V-8HD)

68H

4th byte of model ID (V-8HD)

11H

Command ID (RQ1)

aaH

Address upper byte

bbH

Address middle byte

ccH

Address lower byte

ssH

Size upper byte

ttH

Size middle byte

uuH

Size lower byte

sum Checksum
F7H

EOX (end of exclusive)

* Depending on the data type, the amount of single-time transmission is specified.

It is necessary to execute data request according to the specified first address and
size. Refer to the “2. Parameter Address Map” (p. 97) for address and size.

* See “Example of an Exclusive Message and Calculating a Checksum” (p. 107) for

checksum.

7

Data Set 1 (DT1)

This is the message of actual data transmission. Use this when you want to set data
to the unit.

Status

Data Byte

Status

F0H

41H, 10H, 00H, 00H, 00H, 68H, 12H, aaH,

F7H

bbH, ccH, ddH, ..., eeH, sum

Byte

Explanation

F0H

Exclusive Status

41H

Manufacturer ID (Roland)

10H

Device ID

00H

1st byte of model ID (V-8HD)

00H

2nd byte of model ID (V-8HD)

00H

3rd byte of model ID (V-8HD)

68H

4th byte of model ID (V-8HD)

12H

Command ID (DT1)

aaH

Address upper byte

bbH

Address middle byte

ccH

Address lower byte

ddH

Data: actual data to transmit. Multiple byte data is sent in address order.

:

:

eeH Data
sum Checksum
F7H

EOX (end of exclusive)

* Depending on the data type, the amount of single-time transmission is specified.

It is necessary to execute data request according to the specified first address and
size. Refer to the “2. Parameter Address Map” (p. 97) for address and size.

* See “Example of an Exclusive Message and Calculating a Checksum” (p. 107) for

checksum.

* Data exceeding 256 bytes should be divided into packets of 256 bytes or smaller. If

you send data set 1 successively, set interval of 20 ms or longer between packets.