Switch b-5: binary preset access, Switch b-6: dependent/independent presets – High End Systems High End LCD Controller for Studio Color User Manual

Page 41

Advertising
background image

Studio Color LCD Controller

Setting the Switches

2-7

2

Switch B-5: Binary Preset Access

Switch B-5 Off (default) – (Twelve-level preset access.) An
analog controller accesses each of 8 presets on 12
independent levels for a total of 96 presets. You must also
select preset level access by setting switch B-3 ON.

Switch B-5 On – When switch B-5 is ON, an analog
controller accesses the first 10 of the 12 analog input
channels in binary combinations to provide remote access to
1023 presets. You must also select preset level access by
setting switch B-3 ON.

Channels 11 and 12 control blackout and standby, as shown
below:

Channel 11 (blackout): closes all fixtures’ shutters but
wheels and effects continue to run.

Channel 12 (standby): activating channel 12 when the
controller is in standby (Standby LED is ON) takes the
controller out of standby. Activating channel 12 when
the controller is not in standby (Standby LED is OFF) has
no effect. When the controller is in standby, all fixtures’
shutters close and any in-progress wheel and effect
changes stop immediately. Controller pages continue to
advance.

Switch B-6: Dependent/Independent Presets

Switch 6 sets the mode of the presets as they relate to the
master controller.

Switch B-6 Off (default) – Dependent Presets; the controller
behaves as follows:

The master controller’s master intensity setting controls
slaves.

Slaved controllers’ modulation effects respond to audio
input at the master controller.

Presets use their programmed master intensity value.

Advertising