Examples, Figure 212 . each of the eight fixtures connected – High End Systems High End LCD Controller for Studio Color User Manual

Page 51

Advertising
background image

Studio Color LCD Controller

Connecting Fixtures

2-17

2

A serial data distributor must be used if either of the
following is true:

You wish to connect more than 32 fixtures to a
controller or more than 32 master/slave controllers
together.

The end-to-end cable span (the total length of all
cables) on any link exceeds 500 ft. (153 m).

The serial data distributor regenerates and retimes the signal;
failure to use it can result in data errors.

Examples

Example #1: One controller is connected to 8 fixtures, each
of which will respond independently to control commands.

Figure 2-12. Each of the eight fixtures connected to
this controller responds independently to control
commands.

The example above shows one Studio Color LCD controller
connected to 8 Studio Color fixtures. Each fixture is
numbered 1 through 8 using the fixture’s menus (see
“Configuring the Fixtures” on page 2-9). A terminator must
be attached to the Data Out connector of the last Studio Color
fixture in the link (see “Terminators” on page 2-16).