Studio Color LCD Controller

Rack Mounting the Controller 2-25

2

Rack Mounting the Controller

After configuring the controller and connecting cables as
described earlier in this chapter, you can mount the Studio
Color LCD controller in a standard 19-inch rack as described
in this section.

The Studio Color LCD controller is designed to mount into a
standard 19-inch equipment rack as specified by the MIL-
STD-189 and ANSI/EIA RS-310-C-77 specifications. The
unit occupies four standard rack spaces.

1.

Insert the unit into the front of the equipment rack. There
must be at least 7 inches of available rack space. Be sure to
feed the power cord in first, being careful not to pinch or
otherwise damage the power cord. Do not use the unit if the
power cord is damaged.

2.

Attach the unit to the equipment rack by placing mounting
screws through the two mounting holes behind the handles on
each side of the controller. Attach the unit by the lower two
mounting holes first as this is where the majority of weight is
supported. Finish by attaching the unit through the remaining
two holes.

3.

The primary disconnect on this device is the power cord. The
cord should be accessible or be placed into a power strip with
an accessible on/off switch.