Refer to drawing 83012612 – FARGO electronic C16 User Manual

Page 193

Advertising
background image

RESTRICTED USE ONLY

Fargo Electronics, Inc.

Persona C16 Card Printer Service Manual (Rev. 5.0)

184

Replacing the Lower Ribbon Sensor Assembly — C16 (83012612)

Refer to Drawing 83012612

Estimated Repair Time: 15 minutes.

Steps Procedures

1

Caution: Turn off the Printer and unplug the power cord from the

Printer.

2

Open the Upper Imaging Assembly.

3

Loosen the top two corner screws (130987) found just behind the top edge of
the Rear Cover.

4

Close the Upper Imaging Assembly.

5

Remove the screw (130987) by the Card Exit Ramp.

6

Remove the Rear Cover.

7

Remove the two screws (130971) that secure the Print Circuit Board to the two
Standoff screws (140047).

8

Remove the screws that hold the Main Board Brackets in place.

9

Use the thumb and index fingers of both hands to carefully pry the Print Circuit
Board from the Power Circuit Board.

10

Remove the screw (130971) that holds the Lower Ribbon Sensor Assembly to
the Rear Side Plate.

11

Disconnect the cable connector from J12, pins 1and 2 on the Print Circuit Board.

12

Remove the LED Board Assembly from the Bottom Sensor Bracket and the
Printer.