Board errors, Resolving the ee memory error, Resolving the dram memory error – FARGO electronic C16 User Manual

Page 215: Sensor testing, Resolving the ee memory, Error

Advertising
background image

RESTRICTED USE ONLY

Fargo Electronics, Inc.

Persona C16 Card Printer Service Manual (Rev. 5.0)

206

Board Errors

Resolving the EE Memory Error

Symptom: An error has occurred in the permanent circuit memory.

Step Procedure

1

Reboot the Printer.

2

If the problem persists, the Main Print Board will need to be replaced. See

Replacing the Main Board

procedure in Section 5, page 164.

3

As an alternative to replacing the Main Print Board, the chip U1 (080196) may be
replaced. (Note: Fargo recommends that only a qualified electronics technician
perform this procedure.)

Resolving the DRAM Memory Error

Symptom: An error has occurred in the removable memory module (SIMM).

Step Procedure

1

Reboot the Printer.

2

If the problem persists, the Main Print Board will need to be replaced. See

Replacing the Main Board

procedure in Section 5, page 164.

3

As an alternative to replacing the Main Print Board, the chip U23 (080194) may
be replaced. (Note: Fargo recommends that only a qualified electronics
technician perform this procedure.)

Sensor Testing

Step Procedure

1

Check the voltage to determine if a Sensor is working.

2

a. Test the voltage of each Sensor using ground (GRD = Chassis) unless noted

to the correct pin on each connector. See Sensor Location and Voltages
table on the next page.

b. Block a Slot Sensor with a card.

c. Depress a switch style Sensor.

Advertising