Motorola ColdFire MCF5281 User Manual

Page 279

Advertising
background image

Synchronous DRAM Controller Module

Freescale Semiconductor

15-7

10–8

CBM

Command and bank MUX [2:0]. Because different SDRAM configurations cause the command and
bank select lines to correspond to different addresses, these resources are programmable. CBM
determines the addresses onto which these functions are multiplexed.
Note: It is important to set CBM according to the location of the command bit.

This encoding and the address multiplexing scheme handle common SDRAM organizations. Bank
select bits include a base bit and all address bits above for SDRAMs with multiple bank select bits.

7

Reserved, should be cleared.

6

IMRS Initiate mode register set (

MRS

) command. Setting IMRS generates a

MRS

command to the associated

SDRAMs. In initialization, IMRS should be set only after all DRAM controller registers are initialized
and

PALL

and

REFRESH

commands have been issued. After IMRS is set, the next access to an SDRAM

block programs the SDRAM’s mode register. Thus, the address of the access should be programmed
to place the correct mode information on the SDRAM address pins. Because the SDRAM does not
register this information, it doesn’t matter if the IMRS access is a read or a write or what, if any, data is
put onto the data bus. The DRAM controller clears IMRS after the

MRS

command finishes.

0 Take no action
1 Initiate

MRS

command

5–4

PS

Port size. Indicates the port size of the associated block of SDRAM, which allows for dynamic sizing of
associated SDRAM accesses. PS functions the same in asynchronous operation.
00 32-bit port
01 8-bit port
1x 16-bit port

3

IP

Initiate precharge all (

PALL

) command. The DRAM controller clears IP after the

PALL

command is

finished. Accesses via IP should be no wider than the port size programmed in PS.
0 Take no action.
1 A

PALL

command is sent to the associated SDRAM block. During initialization, this command is

executed after all DRAM controller registers are programmed. After IP is set, the next write to an
appropriate SDRAM address generates the

PALL

command to the SDRAM block.

2–0

Reserved, should be cleared.

Table 15-5. DACRn Field Descriptions (continued)

Bit

Name

Description

CBM

Command Bit

Bank Select Bits

000

17

18 and up

001

18

19 and up

010

19

20 and up

011

20

21 and up

100

21

22 and up

101

22

23 and up

110

23

24 and up

111

24

25 and up

MCF5282 and MCF5216 ColdFire Microcontroller User’s Manual, Rev. 3