Queued Analog-to-Digital Converter (QADC)

Freescale Semiconductor

28-59

Figure 28-46. External Positive Edge Trigger Mode Timing with Pause

A time separator is provided between the triggers and the end of conversion (EOC). The relationship to
QCLK displayed is not guaranteed.

CWPQ1 and CWPQ2 typically lag CWP and only match CWP when the associated queue is inactive.
Another way to view CWPQ1 and CWPQ2 is that these registers update when EOC triggers the write to
the result register.

For the CCW with the pause bit set (CCW0), CWP does not increment until triggered. For the CCW with
the pause bit clear (CCW1), the CWP increments with the EOC.

The conversion results Q1 RESx show the result associated with CCWx, such that R0 represents the result
associated with CCW0.

Figure 28-47

shows the timing for conversions in externally gated single-scan with same assumptions in

example 1 except:

No pause bits set in any CCW

Externally gated single scan mode for Q1

Single scan enable bit (SSE1) is set.

When the gate closes and opens again, the conversions start with the first CCW in Q1.

When the gate closes, the active conversion completes before the queue goes idle.

When Q1 completes, both the CF1 bit sets and the SSE bit clears.

In this mode, the PF1 bit sets to reflect that a gate closing occurred before the queue completed.

Figure 28-48

shows the timing for conversions in externally gated continuous scan mode with the same

assumptions as in

Figure 28-47

.

R1

LAST

R0

CCW0

CCW1

CCW2

CCW1

CONVERSION TIME

TIME BETWEEN

QCLK

TRIG1

EOC

QS

CWP

CWPQ1

Q1 RES

0

LAST

8

4

8

CCW0

TRIGGERS

= 14 QCLKS

CONVERSION TIME
= 14 QCLKS

MCF5282 and MCF5216 ColdFire Microcontroller User’s Manual, Rev. 3