Debug Support

30-24

Freescale Semiconductor

Command Sequence

Figure 30-20.

WAREG

/

WDREG

Command Sequence

Operand Data

Longword data is written into the specified address or data register. The data is
supplied most-significant word first.

Result Data

Command complete status is indicated by returning 0xFFFF (with S cleared)
when the register write is complete.

30.5.3.3.3

Read Memory Location (

READ

)

Read data at the longword address. Address space is defined by BAAR[TT,TM]. Hardware forces
low-order address bits to zeros for word and longword accesses to ensure that word addresses are
word-aligned and longword addresses are longword-aligned.

WAREG/WDREG

???

LS DATA

’NOT READY’

NEXT CMD

’NOT READY’

XXX

BERR

MS DATA

’NOT READY’

NEXT CMD

’CMD COMPLETE’

MCF5282 and MCF5216 ColdFire Microcontroller User’s Manual, Rev. 3