Malfunction code

Main Unit Field Service

4-10

IV

T

roub

lshoo

t

in

g

004EH LV Cooling Fan Motor malfunction

• The Motor Lock signal remains HIGH for a given period

of consecutive time while the LV Cooling Fan Motor is
being rotated.

0060H Fusing Motor malfunction

• The Fusing Motor does not rotate evenly even after the

lapse of a given period of time while it is being started.

• The Motor Lock signal remains HIGH for a given period

of consecutive time while the Fusing Motor is being
rotated.

0094H

2nd image transfer pressure/
retraction failure

• The Retraction Position Sensor/2nd Image Transfer is

not activated (retracted position) within a given period
of time after the retraction sequence of the 2nd Transfer
Roller has been started.

• The Retraction Position Sensor/2nd Image Transfer is

not deactivated (pressed position) within a given period
of time after the pressure sequence of the 2nd Transfer
Roller has been started.

0096H

1st image transfer pressure/
retraction failure

• The Retraction Position Sensor/1st Image Transfer is

not activated (retracted position) within a given period
of time after the Intermediate Transport Motor has
started rotating.

• The Retraction Position Sensor/1st Image Transfer is

not deactivated (pressed position) within a given period
of time after the Intermediate Transport Motor has
started rotating.

0300H Polygon Motor malfunction

• The Polygon Motor does not rotate evenly even after

the lapse of a given period of time after it has been
started.

• The Motor Lock signal remains HIGH for a given period

of consecutive time while the Polygon Motor is being
rotated.

0310H Laser malfunction

• The SOS signal is not detected within a given period of

time after the output of the laser has been started.

0500H Heating Roller warm-up failure

• The Heating Roller Thermistor does not detect the

specified temperature and the warm-up cycle is not
completed even after the lapse of a given period of time
after the cycle has been started.

0501H

Fusing Pressure Roller warm-up
failure

• The Fusing Pressure Roller Thermistor does not detect

the specified temperature and the warm-up cycle is not
completed even after the lapse of a given period of time
after the cycle has been started.

0510H

Abnormally low Heating Roller
temperature

• The temperature detected by the Heating Roller Ther-

mistor remains lower than the specified value for a
given period of time or longer.

0511H

Abnormally low Fusing Pressure
Roller temperature

• The temperature detected by the Fusing Pressure

Roller Thermistor remains lower than the specified
value for a given period of time or longer.

0520H

Abnormally high Heating Roller
temperature

• The temperature detected by the Heating Roller Ther-

mistor remains higher than the specified value for a
given period of time or longer.

Code

Item

Detection Timing